AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2

AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2

You have chosen to download our software.

Within a few seconds, you will receive an email containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

1.3.0.8

Target Support Package for installation in CODESYS.

This version relates specific to CODESYS ver. 3.5.15.20

 

Added

  • CODESYS OPC UA Server (SP18 and newer)
  • Updated IFM61 devdesc to v1.1.0.0, revision 9
  • Updated CMM62 devdesc to v0.9.0.2, revision 2
  • Updated SIM61 devdesc to v1.0.0.1, revision 2
  • Updated SIM62 devdesc to v1.0.0.0, revision 2
  • Updated SIM63 devdesc to v1.0.0.1, revision 2
  • Added DOM61 devdesc to v0.2.0.0, revision 2
  • Added DIM61 devdesc to v0.1.0.0, revision 1
  • Added DIO62 devdesc to v0.1.0.0, revision 1

 

Corrections

  • Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1
  • Fix scan/copy all devices SIM6.2

1.3.0.8

08. 08. 2023

Target Support Package for installation in CODESYS.

This version relates specific to CODESYS ver. 3.5.15.20

 

Added

  • CODESYS OPC UA Server (SP18 and newer)
  • Updated IFM61 devdesc to v1.1.0.0, revision 9
  • Updated CMM62 devdesc to v0.9.0.2, revision 2
  • Updated SIM61 devdesc to v1.0.0.1, revision 2
  • Updated SIM62 devdesc to v1.0.0.0, revision 2
  • Updated SIM63 devdesc to v1.0.0.1, revision 2
  • Added DOM61 devdesc to v0.2.0.0, revision 2
  • Added DIM61 devdesc to v0.1.0.0, revision 1
  • Added DIO62 devdesc to v0.1.0.0, revision 1

 

Corrections

  • Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1
  • Fix scan/copy all devices SIM6.2

1.3.0.7

20. 04. 2023

Run-time software for CODESYS on a PCM5.2 board

This version relates specific to CODESYS ver. 3.5.15.20

 

Changes

• Open62541 upgraded to v1.3.4.

 

New features

• CODESYS runtime v3.5.18.40.
• Added support for CODESYS OPC UA Client SL.
• Added support for CODESYS OPC UA Server SL.
• Added support for CODESYS RTU Master.
• Added support for CODESYS RTU slave.

 

Corrections

• Fixed unresolved references in CmpFFT library.
• Deprecated DEIF_FileIO.compiled-library.
• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.

1.3.0.4

15. 07. 2022

Run-time software for CODESYS on a PCM5.2 board

This version relates specific to CODESYS ver. 3.5.15.20

 

Initial release.

DEIF 제품을 완전하게 활용하기 위해서는 DEIF에서 제공하는 업데이트를 설치하도록 항상 권장하고 있습니다.

업데이트된 소프트웨어는 언제나 무료로 www.deif.com의 “소프트웨어”에서 “소프트웨어 내려받기”를 통해 내려받기할 수 있습니다.

질문 또는 제품 관련 소프트웨어에 관한 문의는 DEIF A/S +45 96149614 또는 해당 지역의 DEIF 사무소로 연락해 주시기 바랍니다. 그 외에도, support@deif.com로 이메일을 보내 주시면 언제든지 도와드릴 준비가 되어 있습니다.