Multi-line 2 AGC-4 Mk II Application Software
Multi-line 2 AGC-4 Mk II Application Software
You have chosen to download our software.
Within a few seconds, you will receive an email containing a download link.
Having trouble using the software? Please contact support@deif.com.
Best regards,
DEIF A/S
The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software
6.15.0
USW version required: 3.61.0
TDU version required: 1.4.3.0
PM compatibility: 1.35.1
New features
- CIO 308 inputs set up as binary types can now be used the same way as CIO 116 digital inputs.
- EIC: Added support for Wise13.
- EIC: Added support for Caterpillar ADEM5.
- EIC: Added support for YC-ECU-A including new delta alarms and views.
- Added M-Logic commands for enabling and disabling parameters 7502 Comm. bus control f, 7503 Comm. bus control U, 7504 Comm. bus control cosphi, and 7505 Comm. bus control Q.
- Added M-Logic commands "Force Gen Start in AUTO" and "Force GB ON in AUTO" in the DG controller.
Changes
- EIC: Added new M-Logic events and AT texts to John Deere Stage V.
Corrections
- GENSET: Corrected an issue with calculating the load impact for single DGs in emulation.
- GENSET: Soft voltage recovery and I stator limitation now works regardless of the configuration of the DVC 550/D550 and DVC 350.
- MAINS: 'Mains power' measurement in datatracer now scales correctly based on the 9030 Scaling parameter.
- EIC: Added Yanmar PJ: X11 engine protocol.
- M-Logic commands 'Inh. start button', 'Inh. stop button', 'Inh. GB/TB button' and 'Inh. MB button' can now be read by the TDU.
- Corrected an issue that caused parameter 2024 Sync. dUMin to be disregarded as a lower limit for dynamic synchronisation of the voltage if parameter 2023 Sync. dUMax was numerically smaller.
- Assigning an analogue output parameter to an already assigned analogue output would fail. Now the newly assigned parameter will be assigned as the analogue output and the parameter the output was previously assigned to will be cleared.
- CIO 308 ID 4 and 5 can now also be used for remote sensing P, Q and U. Fixed an issue for remote sensing with the mains controller, where the wrong transducer min/max was used for U remote sensing.
- GPPIDs can now be used with all IOM CAN ID outputs again. The parameter for specifying which IOM to use for GOV, AVR and load share can be found in the 'IOM configuration' tab of the 'ECU & D-AVR configuration' page.
- Corrected PMS redundant with BTBs so the redundant unit follows the preferred unit.
- The synchronisation module now correctly determines when to close the breaker during dynamic synchronisation in configurations where the breaker close time is high (parameters 2025 and 2026).
6.15.0 |
03. 12. 2024 |
USW version required: 3.61.0 PM compatibility: 1.35.1 New features
Changes
Corrections
|
6.14.0 |
27. 09. 2024 |
IMPORTANT: This software requires USW-3 version 3.60.2 with PDB revision 10901 or higher. PM compatibility: 1.35.1 New features:
Changes:
Corrections:
|
6.13.1 |
15. 07. 2024 |
PM compatibility: 1.34.0 Corrections1- Corrected unit restarting if Profibus option is selected. |
6.13.0 |
18. 06. 2024 |
PM compatibility: 1.34.0 New features 1- Fuel optimisation further optimised in more applications, including PV and battery. Changes 1- Spinning reserve stop hysteresis calculation is now based on the nominal power on busbar after next DG to stop.
Corrections 1- Auto calculation multistarts with fuel optimisation, now works before the TB is closed. |
6.12.1 |
26. 02. 2024 |
PM compatibility: 1.34.0 Corrections
|
6.12.0 |
30. 10. 2023 |
PM compatibility: 1.32.0 New features• EIC: Added support of Weichai E6. Changes• EIC: Added GTACP (0xFE05, SPN2452/2460) to Caterpillar generic and Perkins generic. Corrections• PMS priority update in 32DG application now working correctly. |
6.11.3 |
21. 09. 2023 |
PM compatibility: 1.30.1 Corrections
|
6.11.2 |
14. 09. 2023 |
PM compatibility: 1.30.1 Corrections
|
6.11.1 |
21. 07. 2023 |
PM compatibility: 1.30.0 Corrections
|
6.11.0 |
11. 07. 2023 |
PM compatibility: 1.30.0 New features
Changes
Corrections
|
6.10.2 |
25. 05. 2023 |
PM compatibility: 1.29.0 Corrections
|
6.10.1 |
23. 03. 2023 |
PM compatibility: 1.29.0 Corrections
|
6.10.0 |
06. 03. 2023 |
PM compatibility: 1.29.0 New features
Changes
Corrections
|
6.09.1 |
20. 01. 2023 |
PM compatibility: 1.29.0 Corrections
|
6.09.0 |
23. 12. 2022 |
PM compatibility: 1.28.0 New features:
Changes:
Corrections:
|
6.08.1 |
13. 12. 2022 |
PM compatibility: 1.28.0 Corrections:
|
6.08.0 |
17. 11. 2022 |
PM compatibility: 1.28.0 New features:
Changes:
Corrections:
|
6.07.0 |
11. 07. 2022 |
PM compatibility: 1.25.0 New features:
Corrections:
|
6.06.0 |
18. 02. 2022 |
PMS compatibility: 1.25.0 New features: Finetuning: |
6.05.0 |
01. 02. 2022 |
PM compatibility: 1.24.2 New features:
Changes:
Corrections:
|
6.04.3 |
16. 11. 2021 |
PM compatibility: 1.24.1 Corrections:
|
6.04.2 |
10. 11. 2021 |
PM compatibility: 1.24.1 Corrections:
|
6.04.1 |
22. 10. 2021 |
Not UL approved version PM compatibility: 1.24.1 Corrections:
|
6.04.0 |
07. 10. 2021 |
Not UL approved version PM compatibility: 1.24.1 New features:
Changes:
Corrections:
|
6.03.1 |
13. 09. 2021 |
Not UL approved version PM compatibility: 1.24.1
|
6.03.0 |
15. 07. 2021 |
Not UL approved version PM compatibility: 1.24.1 New features:
Changes:
Corrections:
|
6.02.1 |
06. 05. 2021 |
UL approved version PM compatibility: 1.23.0 Corrections:
|
6.02.0 |
06. 04. 2021 |
Not UL approved version PM compatibility: 1.23.0 New features:
Changes:
Corrections:
|
6.01.2 |
15. 03. 2021 |
Not UL approved version PM compatibility: 1.22.0 Corrections:
|
6.01.1 |
12. 02. 2021 |
Not UL approved version PM compatibility: 1.22.0 Corrections:
|
6.01.0 |
11. 01. 2021 |
UL approved version PM compatibility: 1.22.0 New features:
|
6-00-0 |
07. 01. 2021 |
Not UL approved version PM compatibility: 1.22.0 |
DEIF 제품을 완전하게 활용하기 위해서는 DEIF에서 제공하는 업데이트를 설치하도록 항상 권장하고 있습니다.
업데이트된 소프트웨어는 언제나 무료로 www.deif.com의 “소프트웨어”에서 “소프트웨어 내려받기”를 통해 내려받기할 수 있습니다.
질문 또는 제품 관련 소프트웨어에 관한 문의는 DEIF A/S +45 96149614 또는 해당 지역의 DEIF 사무소로 연락해 주시기 바랍니다. 그 외에도, support@deif.com로 이메일을 보내 주시면 언제든지 도와드릴 준비가 되어 있습니다.